Universal testing method for power transformer differential. Use the dmm in ac mode to measure the transformer primary. Commissioning procedure of power transformer in transformer testing it can be classified into power and distribution transformers. It is not a complete stepbystep procedure for performing tests and is not replacing the user manual for the actual instrument. These two transformer tests are performed to find the parameters of equivalent circuit of transformer and losses of the transformer. Before commencement of any test make sure the surroundings near clear off from any unwanted materials etc, and make proper approach, scaffolding etc. The book represented the collective wisdom of over 100 years of testing power transformers. A procedure for investigating the internal pd source is described in.
A static electric device consisting of a winding, or two or more coupled windings, with or without a magnetic core, for introducing mutual coupling between electric circuits. Power transformer maintenance and acceptance testing cmafte n 1. Connect the megohmmeter to one terminal of the h side of the pt and the negative to one side of the x side and to ground. As such, in this paper, a detailed procedure of the throughfault test for power transformer differential circuit prior to substation energization using the practical examples is covered. Energy efficiency program for certain commercial and industrial equipment. Power generation plant monitoring systems fault recorders scada. When personnel investigated the interior of the tank, there was significant degradation of the paper. There are various test required on transformer to conform performance of transformer. Following is an approximate sequence for transformer testing. Insulation resistance test of transformer is divided into three parts.
Mainly two types of transformer are done by manufacturer before dispatching the transformer mainly 1 type test of transformer and 2 routine test. This test also performed as a routine test of transformer. Standard for acceptance testing specifications for electrical. Test voltages used to determine highvoltage power transformer ratios are usually 1 of the windings rated voltage or less to reduce testing hazards. Tm 5686 power transformer maintenance and acceptance. The complete guide to electrical insulation testing. It rating plate show nominal voltage, current of primary and secondary voltage at various of the tap changer, connection symbols vector group, % impedance weight of oil etc. The ratio of power dissipated in the insulation in watts to the product of the effective voltage and current in voltamperes when tested with a sinusoidal voltage. Transformer oil testing by robert turcotte, manager, electrical loss control the hartford steam boiler inspection and insurance company the value of transformer oil testing transformer oil testing is a proven loss prevention technique which should be a part of any conditionbased predictive maintenance program. Also, the troublefree service of the equipment over its life depends on proper installation, operation, and maintenance.
In 2003, abb compiled all its knowledge in a book titled testing of power transformers. Inspect transformer and parts for shipping damage and moisture. It evolved from the simple gonogo verdict into a sophisticated segment within transformer manufacturing. Type test procedure iec, nec, nema, fdf, iso ansi, ci, ipcea iec, nec, nema, fdf, iso ansi, ci, ipcea procedure h r a inspection and test plan for power transformer before manufacturing activity by. Before proceding with transformer measurements the test engineer will become familiar with the safety rules of section 2. The simplest test values to choose are those for which a decimal point reading would read the same as high and lowwinding nameplate kv values. Maintenance of transformers a detailed checklist electrical4u. This amounts to a rigorous examination of the transformer intended to. Stability testing of tansformer ref protection scheme. Mechanical changes to windings, caused for example by transportation, and contact problems at other connections can be detected before first operation. Insulation power factor testing of power transformers.
The megger insulation tester is essentially a highrange resistance meter ohmmeter with a builtin directcurrent generator. High voltage testing 149 the high voltage is applied across the device under test by means of a transformer. Power transformer testing testing of power transformers 1. Transformer test ing allows this aging process to be quantified and. The following tests are routinely conducted in the field on the transformer. The voltage ratio of a transformer is the ratio of the rms terminal voltage of a. Power transformer testing and commissioning guidelinesoil. All transformers are subjected to the following routine tests. Short circuit test and differential stability stable condition. Open circuit and short circuit test on transformer. D r a f t doble engineering company 85 walnut street watertown, massachusetts 024724037 usa pn 5000397 72a2244 rev. Power transformer testing fat test inspection for industry. We perform one group on a routine basis known as preventative maintenance, and the second group on an adhoc basis i. What is the megger test procedure for transformers.
Transformers are extensively used in electric power systems to transfer power by electromagnetic induction between. Connect the 120 v, 60 hz power through the lamp to the transformer primary, terminals as presented in. Jun 27, 2018 power transformer testing automatically measuring ratio and winding resistance of all tapsphases duration. Standard for maintenance testing specifications for electrical power equipment and systems is the most current revision of this document. Measurement of noload loss and current in power transformer. The charge transfer processes between capacitances ct and ck cause a residual voltage dropures. A 40yearold transformer showed a degree of polymerization of 260 in early 2010 during testing, with estimated remaining life at 19 percent. Oil tests in the shop or laboratory would be carried out at room temperature 20o c. Before conducting a transformer winding resistance test, it is important to observe all safety warnings and take proper precautions. A primary part of commissioning a transformer involves testing it after its installation in the field. C electrical power from one voltage to another voltage keeping the frequency same by electromagnetic induction discover the worlds research 17. In this book we have laid down important aspects on transformer.
Mar 29, 2019 confirm the proper input to the transformer. Testing of power transformers seems like a similar experience. Firstly measure insulation resistance between low voltage windings and the main body of the transformer. Field testing of a power transformer before putting into service 50mva. Mlgw began to test each of its transformers for furans in 2009. If the measurement is less than 80 percent of the expected voltage, the fault could lie in either the transformer or the circuitry providing the primary with power. Transformer testing commissioning, routine, diagnostic. Section 7 of the ansineta standard for acceptance testing specifications for electrical power equipment and systems may be reproduced and used on a cut and paste basis for the particular type of equipment to be tested. The ac hv test value should not surpass 75% of the factory test value. Testing potential transformers relay testing training. Power transformer installation, acceptance, and maintenance procedures transformer successful operation depends on correct installation, loading, and.
The typical excitation current test data pattern for a. Pdf transformer is a static device which transforms a. Testing and diagnostics of power transformers brochure. Power transformer oil sampling job safety analysis.
Powerfactor or dissipationfactor tipup exceeding 1. Turnsratio test results should not deviate more than onehalf percent from either the adjacent coils or the calculated ratio. Nov 17, 2019 a power transformer requires various routine maintenance tasks including measurement and testing of different parameters of the transformer. So transformer ratio test is an essential type test of transformer. To ensure that the product is fit for its intended use standards iec standards iec 60076 part 1 part 14 specification for transformers ieee. The amperage rating for your transformer fuse may be labeled on the transformer, but will also be. Transformer ct testing as test equipment becomes more sophisticated with better features and accuracy, we risk turning our field personnel into test set operators instead of skilled field service technicians. A power transformer requires various routine maintenance tasks including measurement and testing of different parameters of the transformer. Power transformer testing transformers may be tested using ac or dc voltage. Standard for testing specifications electrical power.
Power transformer testing swp check this is the latest process zone version before use. By means of cascading, the size of the transformer and the insulation bushing. Power transformer testing procedures and schemes photo credit. Routine tests are carried out on every unit manufactured. Feb 08, 2015 a routine test of transformer is mainly for confirming operational performance of individual unit in a production lot. We use megger test at low voltage side as shown in fig. Insulation resistance tests megger test are carried out on all windings, core and core clamping bolts. The following sections of the ansineta standard for acceptance testing specifications for. In any pd test circuit, the real measurable charge qm integral of the circulating pd current it, is dependent 80 ontheratioofcouplingcapacitancecktotestobjectcapacitancect,seefigure9. The quality of a transformer is of utmost importance for safety, industrial and financial reasons. The megger insulation tester is a small, portable instrument that gives you a direct reading of insulation resistance in ohms or megohms.
May 10, 20 so transformer ratio test is an essential type test of transformer. This guide provides a general overview of the regulatory framework and approval process and explores the specific manufacturing responsibilities and test procedures associated with electrical safety testing. The doe issued a rule that defines these transformers and how manufacturers must comply. The objective of testing is to ensure quality to ensure that the products manufactured have met the requirements of customer specificationstandard to prevent accidents which may occur if a failed product is put into service. Routine tests and type tests of transformers electrical4u. For voltages above 123 kv and for high values of rated power usually above 100 mva, for handling and econo mic reasons it is usual to use single phase transformers. The ansineta standard for maintenance testing specifications for electrical power equipment and systems was developed for use by those responsible for the continued operation of existing electrical. To understand the nature of ratio testing it is important to understand the applicable definitions. The goal of partial discharge measurement is to certify that no harmful partial discharge sources exist.
In this book we have laid down important aspects on transformer testing in order to enhance the understanding of the testing procedures and its outcome. This transformer testing method is used to give an indication of the condition dryness of the transformer insulation. Way more information than you ever wanted on how to fell a tree. A free powerpoint ppt presentation displayed as a flash slide show on id. Ensure that all equipment to be tested is properly grounded and treat all highvoltage power equipment as energized until proven otherwise by using the proper lockouttagout procedures. The established documentation for the elimination and control of hazards is henceforth referred to as electrical safety procedure.
Common electrical tests on power transformers omicron. Test code for liquidimmersed distribution, power, and regulating transformers 1 and ieee std 621995 to be changed to c57. Ieee standard terminology for power and distribution transformers. Test this by hooking up the secondary to its circuit and using your dmm to test the secondary lines. Note that secondary ct currents, for such main ct connections as shown in figure 5b, have exactly the same phase angle relationship as the primary currents from the two power transformer sides see figure 4. There are two main types of maintenance of transformer. The procedure of the transformer ratio test is simple. Open circuit test and short circuit test on transformer are very economical and convenient because they are performed without actually loading of the transformer. Power transformer testing procedures and schemes eep.
Transformer testing has developed considerably over the past years. Back to the basics current testing relay testing training. The following should be expected on chl power factors. Ch and cl powerfactor or dissipationfactor values will vary due to support insulators and bus work utilized on dry transformers. In addition some other tests are also carried out by the consumer at site before commissioning and also periodically. Ac voltage is preferable to dc voltage for transformer testing because ac voltage simulates the internal stress that the transformers face during operating conditions. Hv earth isolate the power supply to the transformer. The transformer was immediately taken offline and internally inspected to identify any problems. Testing circuit and procedures are important to follow as per manual to avoid any. So for ensuring proper performance of electrical power transformer, voltage and turn ratio test of transformer one of the important tests.
This ms excel spreadsheet is actually detailed instruction for each procedure necessary for correct testing of power transformer. Page 2 of 14 standard work practice sp0504 ver 4 ergon energy corporation limited abn 50 087 646 062 ergon energy queensland pty ltd abn 11 121 177 802 sm0701. The standard megger testing equipment is used, the line terminal of which is connected to the winding or core bolt under test. Once the phase angle relationship between the two ct secondary currents is known. Test procedures, labeling, and the certification requirements for electric motors. If the reading is above the amperage rating for the transformer, the circuit is drawing too much power. Consult transformer manufacturers or test equipment. C electrical power from one voltage to another voltage keeping the frequency same by.
Procedure h r a 9 power transformer temperature rise test. One must assure that the test cell is clean and it is a wise precaution to bleed the sampling tube to assure a representative sample. Cables connected at lv cable box, feedin g the load of the connected power system. The polarity of singlephase transformers and connection symbol of threephase transformers shall be checked in each winding. Basics, maintenance, and diagnostics xi contents continued page 9. Applicable to tata power operating and project sites which cover but not limited to plant premises, switchyards, substations, offices. For good insulation, the resistance usually reads in the megohm range. Testing of high voltage cables manual horizon power. Common electrical tests on power transformers before the initial use of a transformer acceptance tests are required for confirming that it is working properly to guarantee safe operation. The test setup and procedure of the frsl test is the same as for shortcircuit. If a very high voltage is required, the transformer is usually build up in stages by cascading.
Open circuit or no load test on transformer open circuit test or no load test on a transformer is. The voltage ratio shall be measured on each tapping and verified aginst manufacturer approved power transformer testing procedure. Standard for acceptance testing specifications for. A test set operator connects the leads, pushes the buttons, and records the results. When ac hipot tests are used for routine maintenance, the power transformer can be examined at rated voltage for 3 min instead of testing at 65% of factory test voltage.
657 1303 1249 412 767 1474 909 1215 1393 1182 854 33 779 362 1511 1183 510 1250 936 1082 370 145 125 437 136 843 1398 412 907 1068 1107 634 167 274 1395 876